Health CareCompany Update
Anteris Technologies Global Corp. (ASX: AVR) Reports 1% Heart Failure Hospitalisation in DurAVR Study
Anteris reported a 1% heart failure hospitalisation rate and single-digit pressure gradients at one year in 100 DurAVR patients. A 1,000-patient randomised trial will provide the key comparison with marketed valves.
![[ASX: AVR] ANTERIS TECHNOLOGIES GLOBAL CORP. a catheter-based heart valve procedure in a modern clinical operating suite, framed around gloved cardiology staff](/media/hero/d245b0d4-9eda-4c0c-949d-e6f262c6a7ea/1795392622647-21a7c63b-1536w.webp)
Listen to article
0:00 / 2:45Anteris Technologies Global Corp. has reported a 1% heart failure hospitalisation rate at one year among 100 patients treated with its investigational DurAVR transcatheter heart valve, adding longer-term clinical evidence ahead of a pivotal head-to-head trial.
The pooled study population had severe aortic stenosis and small aortic annuli, an anatomy associated with elevated pressure gradients and prosthesis-patient mismatch following transcatheter aortic valve replacement. The patients came from Anteris’ EMBARK and early feasibility studies in the United States and Europe, rather than a randomised comparison.
At one year, the DurAVR valve maintained a mean pressure gradient of 8.9 mmHg, down from 48.1 mmHg at baseline. Mean effective orifice area increased from 0.8 cm² to 2.2 cm².
No moderate or severe paravalvular leak or haemodynamic valve deterioration was observed, and no valve-related deaths were reported. All-cause mortality was 6%, while the rates of stroke and new permanent pacemaker implantation were 3% and 9%, respectively.
Symptoms and cardiac remodelling
The proportion of patients in New York Heart Association class I or II increased from 39% at baseline to 96% after one year, with 81% experiencing an improvement in symptoms. Before treatment, 61% were in class III or IV, indicating marked limitation or symptoms at rest.
At 30 days, 97% of patients were free from moderate or severe prosthesis-patient mismatch, which occurs when an implanted valve’s effective opening is too small relative to the patient’s body size.
A cardiac magnetic resonance substudy involving 64 patients found that left ventricular mass declined by 24% over one year. Anteris said the finding was consistent with sustained unloading of the heart, although the pooled early-stage results may not predict the outcome of the pivotal study.
The data were presented at PCR London Valves 2026. Anteris noted that the 1% heart failure hospitalisation rate was below rates reported in contemporary trials of marketed valves, but cross-trial comparisons involve different patient groups and study designs.
Pivotal trial is the next test
DurAVR is now being assessed in the PARADIGM trial, a prospective randomised study comparing the device directly with commercially available transcatheter aortic valves in the United States and Europe.
The trial is designed to enrol approximately 1,000 patients, randomised equally between DurAVR and approved competing valves. It will test non-inferiority using a one-year composite endpoint covering all-cause mortality, all stroke and cardiovascular hospitalisation.
DurAVR is Anteris’ lead product and uses the company’s ADAPT anti-calcification tissue technology. The balloon-expandable valve is intended to mimic the shape and blood-flow performance of a healthy aortic valve.
The device remains investigational and is not available for commercial use or sale. That leaves PARADIGM as the central test of whether the favourable haemodynamic and clinical outcomes reported in the pooled 100-patient cohort hold up against established valves in a randomised setting.
Latest ANTERIS TECHNOLOGIES GLOBAL CORP. ASX Announcements
- 23 Nov 2026 · 9:03 amCompany Update
- 11 Nov 2026 · 9:16 amPeriodic Reports
- 11 Nov 2026 · 9:12 amPeriodic Reports
- 10 Nov 2026 · 9:12 amMeetings & Governance
- 10 Nov 2026 · 9:03 amPeriodic Reports
- 6 Nov 2026 · 9:50 amSecurities Administration
- 5 Nov 2026 · 1:46 pmSecurities Administration
- 2 Nov 2026 · 9:40 amCompany Update
![[ASX: ACW] ACTINOGEN MEDICAL LIMITED an older clinical-trial participant seated across from a medical researcher during a cognitive assessment, framed at desk](/media/hero/5f03c56a-8eb5-4737-9862-f99b683dad2c/1795058492006-4a0eef46-640w.webp)
![[ASX: LDX] LUMOS DIAGNOSTICS HOLDINGS LIMITED a clinician in an urgent care examination room preparing a fingerstick blood sample beside a compact](/media/hero/14fdc9c1-090a-4cb4-838b-6ccac9e764af/1794196573830-a831dc31-640w.webp)
![[ASX: OCC] ORTHOCELL LIMITED a close-up composition of sustainably sourced pearl shells beside a small sample of processed bone graft biomaterial in](/media/hero/1d78f211-86f4-4939-97eb-81bda5f14669/1793764030563-b679e509-640w.webp)
![[ASX: OMA] OMEGA OIL & GAS LIMITED a wireline logging operation at a deep exploration well, with field technicians working around the](/media/hero/e78b975a-618a-4d21-8b07-1e07a46fcf8e/1795057435210-f10bb085-640w.webp)
![[ASX: FTI] FORTIFAI LTD a close-up of an FPGA circuit board installed within enterprise computing hardware, with connected data cables and rows](/media/hero/8011d2a5-f6a3-4bfe-964e-8ff6969b16e5/1795055492063-6473391f-640w.webp)
![[ASX: EQU] EQUUS ENERGY LIMITED a wide technical cutaway of an offshore gas basin showing established well paths and several adjacent stacked](/media/hero/c3b40ec0-3921-419b-b03f-f771ae196222/1794964746127-937d280b-640w.webp)